CFH-Q Type Marine Pneumatic Fire Damper

1. Features:

  • The fire damper should normal open on getting compressed air & electric power, and should be close on loss of compressed air or electric power, pneumatic operating pressure is 0.5~0.8Mpa.
  • If the temperature of air in damper duct exceeds 70±3°C, the fusible link of fire damper will be broken and the change valve will cut off the compressed air source to close the fire damper.
  • On/off status of control electric source for solenoid change valve could be controlled locally or remotely, thus open/close the fire damper;
  • Manual change valve can be controlled by handle drag line, and the fire damper can close locally or remotely.
  • On/off signal output when the fire damper is on/off.

2. Outline drawing:

CFH-Q type marine pneumatic fire damper

CFH-Q type marine pneumatic fire damper

3. Supply scope:

  • Electric control box: 1 set
  • Junction box:  1 set
  • Pneumatic actuator system 1 set (include: cylinder,change valve, solenoid valve, manual change valve each)
  • The material of cylinder should be aluminum alloy or stainless steel according to user’s requirement;

4. Type & parameter:

A) Rectangular single-blade pneumatic fire damper

Type a x b L Flange size
CFH-Q axb 100×100 ~500×700 ≥250 According to GB1561-79

B) Circular single-blade pneumatic fire damper

Type a x b L Flange size
CFH-Q ø D 100×500 ≥250 According to GB1561-79

C) Rectangular multi-blades pneumatic fire damper

Type a x b L Flange size
CFHD-Q axb 300×400~1600×2000 ≥250 According to GB1561-79

D) Circular multi-blades pneumatic fire damper

Type a x b L Flange size
CFHD-Q ø D 300×1800 ≥300 According to GB1561-79

Note: Flange size of all fire dampers could  be fabricated according to user’s requirements.

 